rejillaselectro rejillaselectro
Plate gratings + round cross-section

Characteristics

• Electrowelded gratings manufactured by means of fully automated processes, resulting in excellent quality products.

• The electrowelded rating is a metallic grill comprised of strips placed sideways, in parallel and connected by round cross-sections welded to one another.

• Supplied in black steel S235 JR; hot galvanization, according to Standard UNE EN ISO 1461:2009.

• Panels are framed in accordance with standard manufacturing measurements.


Applications

• Metallic structures.
• Enclosures.
• Gutters.
• Decoration.
• Treatment stations.

rejillascolgadas

Manufacturing dimensions of standard measurements.

Mesh (mm) Wire-drawing (mm) Portable plate (mm) Panel dimensions
Width (mm) Length (mm)
34 x 38 x 2


34 x 38 x 3
5 30-2


30-3
1000 200
250
300
400
500

600

700
800
900
1000
1500
2000
3000
6100
Tailor-made manufacture.
Contact our technical service.


pletina

Electrowelded grating load table.

Distance between free opening supports in mm.
34x38 mm mesh, plate and round cross-section.


Even load in Kg./m2. Specific panel loadl.

Plate * 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000
20x2 UN 1744 1211 890 618 538 436 360 306 258 222 194 170 151 134 121 109
PU 93 75 62 54 47 42 37 34 31 29 27 25 23 22 21 20
20x3 UN 2713 1884 1384 1060 837 678 561 471 401 301 265 235 235 209 188 170
PU 146 115 97 83 73 65 58 53 49 42 39 36 36 34 32 31
25x2 UN 2725 1892 1390 1064 841 681 563 473 403 347 303 266 236 210 189 170
PU 146 117 98 84 73 65 59 53 49 45 42 39 37 34 33 31
25x3 UN 4240 2940 2163 1656 1308 1060 876 776 627 541 471 414 367 327 293 265
PU 228 182 152 130 114 101 91 83 76 70 65 61 57 54 51 48
30X2 UN 3667 2547 1871 1432 1132 917 758 637 543 468 407 358 317 283 254 229
PU 197 158 131 112 98 87,52 79 72 66 61 56 53 49 46 44 41
30X3 UN 5704 3961 2910 2228 1760 1426 1178 990 843 728 634 557 493 440 395 356
PU 306 245 204 175 153 136 123 111 102 94 88 82 77 72 68 64
35X2 UN 5341 3709 2725 2087 1649 1335 1103 927 790 681 594 522 464 412 370 334
PU 287 229 191 164 143 127 115 104 96 88 82 76 72 67 64 60
35X3 UN 8309 5771 4240 3246 2565 2077 1717 1442 1229 1060 923 811 719 641 575 519
PU 446 357 279 255 223 198 178 162 149 137 127 119 112 105 99 94
35X4 UN 11277 7831 5754 4405 3481 2819 2330 1958 1668 1438 1253 1101 976 870 781 705
PU 605 484 404 346 303 269 242 220 202 186 173 161 151 142 135 127
40X3 UN 10853 7537 5537 4239 3350 2713 2242 1884 1606 1384 1205 1060 939 837 752 678
PU 583 466 388 333 291 259 233 212 197 179 167 155 146 137 130 123
40X4 UN 14729 10228 7515 5715 4546 3682 3043 2557 2179 1879 1637 1438 1274 1137 1020 921
PU 791 633 527 451 395 352 316 288 264 243 226 211 198 186 176 167
40X5 UN 18606 12921 9493 7268 5742 4651 3844 3230 2752 2373 2067 1817 1609 1436 1289 1163
PU 999 799 666 571 499 444 400 363 333 307 285 266 250 235 222 210
50X5 UN 29071 20188 14832 11356 8972 7268 6006 5047 4300 3708 3230 2838 2515 2243 2013 1817
PU 1561 1249 1041 892 780 694 624 567 520 480 446 416 390 367 347 329
*: Distance between supports.
EV: Evenly distributed load, based on opening distance between supports. (Kg. m2)
SP: Specific load on a 200x200mm surface, based on opening distance between supports (Kg per panel)